Table 2. Validation of analytical method for pantothenic acid

Vitamin Sensitivity Precision Recovery and accuracy
LOD1) LOQ2) Repeatability3) Reproducibility4) Reference value6) Analysis value7) Recovery (%) RSD (%)
(μg/mL) RSD (%)5) RSD (%)
Pantothenic acid 0.001 0.003 4.831±0.0028 4.832±0.096 150±12 150.75±0.95 100.5 0.63
LOD, limit of detection; LOD=3×signal/noise.
LOQ, limit of quantification; LOQ=10×signal/noise.
Repeatability refers to the results of 5 independent determinations carried out for the same sample on the same day.
Reproducibility refers to the results of 5 independent determinations carried out on a sample by analyzing 3 replicates of the sample at each day for 5 days.
Relative standard deviation (%).
Reference value is the true value provided by NIST.
Analysis value is the experimental value obtained by HPLC assay for pantothenic acid.