Table 3. The level of indicator bacteria from equipment and glove used for washing and drying red peppers

Process Samples Total bacteria Coliform
A B C Average A B C Average
Washing Washing machine(raw pepper input area) 1.27±1.25a1) 2.20±0.61a 2.80±1.04a 2.09±1.10 0.10±0.17a 1.03±0.93a 1.37±1.72a 0.83±1.13
Washing machine(washing area) 2.97±0.64a 0.73±1.27b 0.33±0.58b 1.34±1.45 2.00±0.53a 0.90±0.85ab 0.00±0.00b 0.97±1.45
Washing machine(rinsing area) 1.17±0.67a 0.50±0.87a 0.00±0.00a 0.56±0.75 0.33±0.58a 0.43±0.75a 0.00±0.00a 0.26±0.51
Container(for collection of washed pepper) 1.27±0.61a 3.13±0.59a 2.03±1.79a 2.14±1.28 0.00±0.00b 1.80±0.26a 0.87±1.50ab 0.89±1.09
Glove 7.73±1.15a 4.03±2.63a 6.60±0.57a 6.06±2.33 > 5.00a 0.63±1.10c 4.85±0.35b 4.60±2.29
Drying in green house Floor in green house 0.00±0.00b 3.17±0.32a 2.87±0.87a 2.02±1.34 0.00±0.00a 0.00±0.00a 0.00±0.00a 0.00±0.00
Drying in dry oven Tray in dry oven 2.00±0.44a 3.33±1.01a 2.37±1.18a 2.57±1.00 0.00±0.00a 0.00±0.00a 0.00±0.00a 0.00±0.00
1)The same letter is not significantly different among the coliform bacterial number of 3 farms at p<0.05 according to Duncan’s test.